{"title":"Jade Bird Power Plant","description":"\u003cp\u003eJade Bird Fire is a manufacturer of addressable and conventional fire detection systems, featuring a complete range of control panels, detectors, and sounders certified for civil and industrial applications.\u003c\/p\u003e\u003cp\u003eIn this category, you will find Jade Bird control panels for fire detection and evacuation management in civil and industrial settings, with a legal warranty and availability indicated for each product.\u003c\/p\u003e","products":[{"product_id":"jbe-p2l11l","title":"Jade Bird 1-loop expandable analogue control panel","description":"\u003cp\u003eJade Bird 1-loop expandable analog control panel - Up to 200 devices per loop - USB for programming and data updating - 7” color LCD display - EN54-2, EN54-4 certified\u003c\/p\u003e\n\n\u003cp\u003e📋 SPECIFICATIONS:\u003cbr\u003e\n• Number of loops: 1 (expandable to 2)\u003cbr\u003e\n• User-selectable loop topologies: Class A (loop) or Class B (line up to 32 devices)\u003cbr\u003e\n• 24 VDC outputs to field devices: 2\u003cbr\u003e\n• Maximum number of devices: 200 (expandable to 400)\u003cbr\u003e\n• Maximum number of output groups: 400\u003cbr\u003e\n• Maximum loop distance: 2,000 m\u003cbr\u003e\n• Recommended cable type: 2 x 1.5 mm² unshielded twisted pair\u003cbr\u003e\n• Maximum number of addressable points: 200 per Class A loop (max 2 x 200)\u003cbr\u003e\n• Loop voltage: 20~30V\u003cbr\u003e\n• Available current per loop: 200 mA\u003cbr\u003e\n• External power outputs: 2 x 2A@24 VDC\u003cbr\u003e\n• Cable entry: Ø20 mm knockouts (14x)\u003cbr\u003e\n• Alarm and Fault outputs: Volt-free normally open relay (up to 2A@30 VDC)\u003cbr\u003e\n• Power supply: 230 VAC (196 – 253 V) 2.5A max.\u003cbr\u003e\n• Protection fuse: 2.5 A\u003cbr\u003e\n• Max. continuous output current (Imax a): 5.5 A\u003cbr\u003e\n• Max. alarm DC output current (max b): 4 A\u003cbr\u003e\n• Battery capacity: 2x 12V 7Ah~12Ah\u003cbr\u003e\n• Operating temperature: -5 to +40 °C\u003cbr\u003e\n• Storage temperature: -20 to +55 °C\u003cbr\u003e\n• Humidity (non-condensing): \u0026lt; 95 %\u003cbr\u003e\n• Protection rating: IP30\u003cbr\u003e\n• Dimensions: 440 (H) x 370 (W) x 126 (D) mm\u003cbr\u003e\n• Weight (without batteries): 4 kg\u003cbr\u003e\n• Standards: EN 54-2 and EN 54-4\u003cbr\u003e\n• DoP: DoP-0370-CPR-3813-1\u003c\/p\u003e\n\n\u003cp\u003e📦 INCLUDED:\u003cbr\u003e\n• Fire alarm control panel• Battery cables• Supervision resistor• Fuses• Access keys• Mounting bracket\u003c\/p\u003e","brand":"JADE BIRD","offers":[{"title":"Default Title","offer_id":58006637183320,"sku":"JBE-P2L1.1L","price":633.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/7765\/7688\/files\/JBE-P2L1.1L.png?v=1787170744"},{"product_id":"jbe-p2l12l","title":"Jade Bird 2-loop analog control panel","description":"\u003cp\u003eJade Bird 2-loop analog control panel - Up to 200 devices per loop - USB for data programming and updates - 7” color LCD display - EN54-2, EN54-4 certified\u003c\/p\u003e\n\n\u003cp\u003e📋 SPECIFICATIONS:\u003cbr\u003e\n• Number of loops: 2\u003cbr\u003e\n• User-selectable loop topologies: Class A (loop) or Class B (line up to 32 devices)\u003cbr\u003e\n• 24 VDC outputs to field devices: 2\u003cbr\u003e\n• Maximum number of devices: 400\u003cbr\u003e\n• Maximum number of output groups: 400\u003cbr\u003e\n• Maximum loop distance: 2,000 m\u003cbr\u003e\n• Recommended cable type: 2 x 1.5 mm² unshielded twisted pair\u003cbr\u003e\n• Maximum number of addressable points: 200 per Class A loop (max 2 x 200)\u003cbr\u003e\n• Loop voltage: 20~30V\u003cbr\u003e\n• Available current per loop: 200 mA\u003cbr\u003e\n• External power supply outputs: 2 x 2A@24 VDC\u003cbr\u003e\n• Cable entry: Ø20 mm knockouts (14x)\u003cbr\u003e\n• Alarm and Fault outputs: Voltage-free normally open relays (up to 2A@30 VDC)\u003cbr\u003e\n• Power supply: 230 VAC (196 – 253 V) 2.5A max.\u003cbr\u003e\n• Protection fuse: 2.5 A\u003cbr\u003e\n• Max. continuous output current (Imax a): 5.5 A\u003cbr\u003e\n• Max. DC alarm output current (max b): 4 A\u003cbr\u003e\n• Battery capacity: 2x 12V 7Ah~12Ah\u003cbr\u003e\n• Operating temperature: -5 to +40 °C\u003cbr\u003e\n• Storage temperature: -20 to +55 °C\u003cbr\u003e\n• Humidity (non-condensing): \u0026lt; 95 %\u003cbr\u003e\n• Protection rating: IP30\u003cbr\u003e\n• Dimensions: 440 (H) x 370 (W) x 126 (D) mm\u003cbr\u003e\n• Weight (without batteries): 4 kg\u003cbr\u003e\n• Standards: EN 54-2 and EN 54-4\u003cbr\u003e\n• DoP: DoP-0370-CPR-3813-1\u003c\/p\u003e\n\n\u003cp\u003e📦 INCLUDED:\u003cbr\u003e\n• Fire control panel• Battery cables• End-of-line resistor• Fuses• Access keys• Mounting bracket\u003c\/p\u003e","brand":"JADE BIRD","offers":[{"title":"Default Title","offer_id":58006637216088,"sku":"JBE-P2L1.2L","price":775.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/7765\/7688\/files\/JBE-P2L1.2L.png?v=1787170745"},{"product_id":"jbe-p2l14le","title":"Jade Bird 4-loop addressable control panel, expandable","description":"\u003cp\u003eJade Bird 4-loop addressable fire alarm control panel, expandable - Up to 8 loops with JBE-P2L2-2LP and JBE-EXP - Up to 200 devices per loop - USB for programming and data updates - 7” color LCD display - EN54-2, EN54-4 certified\u003c\/p\u003e\n\n\u003cp\u003e📋 SPECIFICATIONS:\u003cbr\u003e\n• Number of loops: 4 - (expandable up to 8 with JBE-P2L2-2LP and external JBE-EXP box)\u003cbr\u003e\n• User-selectable loop topologies: Class A (ring) or Class B (spur up to 32 devices)\u003cbr\u003e\n• 24 VDC outputs for field devices: 2\u003cbr\u003e\n• Maximum number of devices: 800 (expandable to 1600)\u003cbr\u003e\n• Maximum number of output groups: 400\u003cbr\u003e\n• Maximum loop distance: 2,000 m\u003cbr\u003e\n• Recommended cable type: 2 x 1.5 mm² unshielded twisted pair\u003cbr\u003e\n• Maximum number of addressable points: 200 per Class A loop (max 2 x 200)\u003cbr\u003e\n• Loop voltage: 20~30V\u003cbr\u003e\n• Current available per loop: 200 mA\u003cbr\u003e\n• External power outputs: 2 x 2A@24 VDC\u003cbr\u003e\n• Cable entry: Ø20 mm knockouts (14x)\u003cbr\u003e\n• Alarm and Fault outputs: Volt-free normally open relays (up to 2A@30 VDC)\u003cbr\u003e\n• Power supply: 230 VAC (196 – 253 V) 2.5A max.\u003cbr\u003e\n• Protection fuse: 2.5 A\u003cbr\u003e\n• Max. continuous output current (Imax a): 5.5 A\u003cbr\u003e\n• Max. DC alarm output current (Imax b): 4 A\u003cbr\u003e\n• Battery capacity: 2x 12V 7Ah~12Ah\u003cbr\u003e\n• Operating temperature: -5 to +40 °C\u003cbr\u003e\n• Storage temperature: -20 to +55 °C\u003cbr\u003e\n• Humidity (non-condensing): \u0026lt; 95 %\u003cbr\u003e\n• Protection rating: IP30\u003cbr\u003e\n• Dimensions: 440 (H) x 370 (W) x 126 (D) mm\u003cbr\u003e\n• Weight (without batteries): 4 kg\u003cbr\u003e\n• Standards: EN 54-2 and EN 54-4\u003cbr\u003e\n• DoP: DoP-0370-CPR-3813-1\u003c\/p\u003e\n\n\u003cp\u003e📦 INCLUDED:\u003cbr\u003e\n• Fire alarm control panel• Battery cables• Supervision resistor• Fuses• Access keys• Mounting bracket\u003c\/p\u003e","brand":"JADE BIRD","offers":[{"title":"Default Title","offer_id":58006637248856,"sku":"JBE-P2L1.4LE","price":1069.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/7765\/7688\/files\/JBE-P2L1.4LE.png?v=1787170746"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1003\/7765\/7688\/collections\/JBE-P2L1.1L_0a04b9c0-f1c1-464b-bf17-d00fc6fab951.png?v=1787098270","url":"https:\/\/elettricity.com\/en\/collections\/centrale-jade-bird.oembed","provider":"Elettricity","version":"1.0","type":"link"}